 Features
I
I I I I
Protects subscribers and equipment from destructive power crosses and lightning surges Reduces frequency of service calls Increases reliability of network operation Reduces cost of network maintenance UL Listed per UL 497*
(R)
1965 Series - 50 Ohm Coaxial Surge Protector
The Bourns 1965 Series Coaxial Surge Protector is intended for use with low power VHF and UHF transmitters, 2-way base station transceivers, and receive-only systems. All models provide GDT technology. The 1965 arrester is symmetric and bidirectional. Either end may be used for the input or output. Various power and voltage choices are available - see specifications below for proper selection. Available with a choice of connectors. Note: The arrester ground plate is common with the connector body; hence the coax cable shields will be grounded at their connection to the arrester.
Characteristics
Characteristic Impedance .................................................................................................................................... 50 Frequency Characteristics (DC - 1 GHz) VSWR (Max.) ................................................................................................................................................... <1.2:1 Transmission/Insertion Loss (Max.) ................................................................................................................. <0.2 dB Impulse Discharge 20 kA, 8/20 s ................................................................................................................................................. 1 time 10 kA, 8/20 s ................................................................................................................................................. 10 times 500 A, 10/1000 s ........................................................................................................................................... 500 times Arc Voltage (during discharge) ............................................................................................................................. 10 V Operating Temperature ........................................................................................................................................ -40 to +85C Maximum Operating Altitude ............................................................................................................................... 7,000 m Impulse Sparkover (100 V/s) 100 V/s ............................................... 1 kV/s ................................................. 10 kV/s ............................................... 1965-20* 400 V ................... 500 V ................... 650 V ................... 1965-35 550 V ................... 650 V ................... 800 V ................... 1965-50 700 V .................. 800 V .................. 900 V .................. 1965-95 1300 V 1450 V 1650 V
*Model 1965-20-Axx is UL Listed per UL 497 for indoor/outdoor use in a listed, compatible NID.
VSWR and Insertion Loss
0 .025 .050
VSWR
1.00 1.02 1.04 1.06
Insertion Loss (-dB)
.075 .100 .125 .150 .175 .200 0 100 200 300 400 500 600 700 800 900 1000
INSERTION LOSS
1.08 1.10 1.12 1.14 1.16
VSWR
Frequency (MHz)
REV. H Specifications are subject to change without notice.
1965 Series - 50 Ohm Coaxial Surge Protector
How to Order How to Order Connector Fittings
Power (Watts)
10 3
Part No. 1965-xx-A00 1965-xx-A01 1965-xx-A04 1965-xx-A05 1965-xx-A12
1965-95 1965-50 1965-35 1965-20 2 4 68 10 5 10 6 107 108 10 9
Description ...... N(f) and N(f) ...... N(f) and N(m) ...... BNC(f) and BNC(f) ...... BNC(f) and BNC(m) ...... UHF(f) and UHF(f)
10 2 8 6 4 2
Frequency (Hz) Note: Radio frequency and transmit power should be known. The above curves apply to systems with a VSWR of 1.2:1 or less. Choose the protector whose curve lies first above the power-frequency coordinates of the radio system. For systems with a VSWR in excess of 1.2:1, or for a more exact determination if desired, multiply the actual radio power by the expression 0.83[2xVSWR/(1+VSWR)]2, and use this new power value to enter the graph.
Product Dimensions
5.3 (.209)
41.0 (1.61)
4.5 DIA. (.177)
3.3 (0.13)
46 (1.81)
57.0 (2.24)
DIMENSIONS:
MM (INCHES)
Asia-Pacific: TEL +886- (0)2 25624117 FAX +886- (0)2 25624116 Europe: TEL +41-41 7685555 FAX +41-41 7685510 North America: TEL +1-909 781-5500 FAX +1-909 781-5700
bourns.com
Specifications are subject to change without notice.
COPYRIGHT(c) 2001, BOURNS, INC. LITHO IN U.S.A. IP 09/01 G0133


▲Up To Search▲   

 
Price & Availability of 1965

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X